ASTM F382 PDF

ASTM F Flexural Fatigue Testing Metallic Bone Plates. After orthopedic reconstructive ASTM F Metallic Angled Orthopaedic Fracture Fixation Devices. Although ASTM F (Four Point Bend) test standard may seem very straight forward, there are specific guidelines you must follow to maintain. Metallic Bone Plates need to undergo several tests before gaining approval as internal fixation devices of the skeletal system. One standard, ASTM F

Author: Arashirn Goltikus
Country: Somalia
Language: English (Spanish)
Genre: Video
Published (Last): 28 September 2018
Pages: 212
PDF File Size: 19.11 Mb
ePub File Size: 15.57 Mb
ISBN: 226-5-41245-958-1
Downloads: 75535
Price: Free* [*Free Regsitration Required]
Uploader: Shakalabar

This test method may be used to determine a fatigue life of the bone plate at either a specific maximum bending moment or over a range of maximum bending moment conditions. Historical Version s – view previous versions of standard. Therefore, the test method is not applicable for testing bone plates under conditions that would approach or exceed the bending strength of the bone plate being tested.

Roller dimensions are another important factor. While on the subject of test setup, we should also discuss the use of rigid extension segments. Active view current version of standard. There are many steps a Test Engineer or Technician can take early in the testing stages to avoid the painful woes of mechanical testing.

Three general items come to mind when performing any mechanical test. By means of our biomedical testing expertise and modular product design, we will help find the testing solution that is right for you.

The asm also presents a catalog of standard specifications that specify material; labeling and handling requirements; and standard test methods for measuring performance related mechanical characteristics determined to be important to the in vivo performance of bone asgm. Therefore, the method is not applicable for testing bone plates made from materials that exhibit non-linear elastic behavior.

The user is cautioned to consider the appropriateness of the standard in view of a particular bone plate and its potential application. The user is cautioned to consider the appropriateness of the standard in view of a particular bone plate and its potential application. F suggests using rollers of equal diameters within the range of 6 to 12 mm. There are occasions when the test f3882 deviate from the spec in order to successfully carry out the experiment.

  INFIX POSTFIX PREFIX CONVERSION PDF

ASTM F382 Flexural Fatigue Bone Plate Fixation Devices Test Equipment

Give one of our application engineers a call today for help with creating the best budget and testing plan according to ASTM F In most instances, only a subset of the herein described test methods will be required. The standard establishes consistent methods to classify and define the geometric and performance characteristics of bone plates.

Static and fatigue forces up to 50 kN 11, lbf Frequency ratings up to 75 Hz R382, all electric actuator for clean test conditions Lower purchase, operating, and maintenance costs than hydraulic equivalents. View more articles about More Sectors. As Mechanical Testing Engineers we can provide valuable insight into when to deviate from a test specification and when not to.

The standard also presents a catalog of standard specifications that specify material; labeling and handling requirements; and standard test methods for measuring performance related mechanical characteristics determined to be important to the in vivo performance of bone plates. The standard calls for a special TestResources test fixture GF that replicates bending movement in a single cycle test, as well as fatigue evaluation of the plate design.

This neither defines the levels of performance or case-specific clinical performance for bone plates, nor describes specific designs for bone v382. By using our website you consent to all cookies in accordance with our Cookie Policy. Instead, the user should only select test methods that are appropriate for a particular device design.

There are instances when we test prototypes and new devices without an established test specification. Link to Active This link will always route to the current Active version of the standard. Become familiar with the test standard asmt order to perform the test accurately. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  BOTHRIOPSIS BILINEATA PDF

When working with the FDA or another regulatory body, one will have to justify their reason for deviating from a specification.

ASTM F – 17 Standard Specification and Test Method for Metallic Bone Plates

No other units of measurement are included in this standard. In most instances, only a subset of the 3f82 described test methods will be required. ASTM does not give any warranty express or implied or make any sstm that the contents of this abstract are accurate, complete or up to date. Instead, the user should only select test methods that are appropriate for a particular device design.

Know when to deviate, and when not to. This abstract is a brief summary of the referenced standard. Referenced Documents purchase separately The documents listed below are referenced within the subject standard f3822 are not provided as part of the standard. For ASTM F testing, the orientation of the bone plate will have a direct effect on the strength of the part in a four point bend scenario.

Make an inquiry today. More content from this author Learn about our Engaged Experts. However, it must be noted that the user is not obligated to test using all of the described methods. Futhermore, it is not the intention of the standard to describe or specify specific designs for bone plates used in the surgical internal fixation of the skeletal system.

Bone plates are used during orthopedic orthopaedic reconstructive surgery for alignment and fixation of bone segments. Rigid extension segments work well to sufficiently lengthen small bone plates so that they can be tested per the four point bend method. By Engaged Expert Maciej Jakucki.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard.